> WWW.UKPMS.COM NOW ARCHIVED
  > Advice Notes
  > Completion of the Core Indicator Pro-Forma for Best Value Road Condition Indicators
  > Condition Ranking
  > Consistency of TTS/SCANNER Results
  > DCD Accreditation Test
  > HMDIF Conversion Software
  > Loading TTS Data - FAQs
  > Misc. Documents
  > OF National Seminar 2004
  > OF National Seminar 2005
  > OF Newsletter
  > Pavement Condition Management Group
  > PCIS Newsletter
  > PCIS Regional Seminars 2009
  > Review of UKPMS Core Functionality
  > Roads Board Advisory Group
  > Roads Board Newsletter
  > SCANNER / TTS Treatment Rules
  > SCANNER Consistency Assessment
  > SCANNER HMDIF Specification
  > SCANNER QA Reports
  > SCANNER Research Reports
  > SCANNER Road Condition Indicator
  > SCANNER Specification 2005/6
  > SCANNER Specification 2006/7
  > SCANNER Specification 2007/8
  > Technical Notes
  > TTS Audit Reports
  > TTS Defects Index Preliminary Analysis
  > TTS Specification
  > UKPMS Annual Health Check 2009
  > UKPMS Health Check 2005
  > UKPMS Health Check 2006
  > UKPMS Health Check 2007
  > UKPMS Health Check 2008
  > UKPMS Rules and Parameters
  > UKPMS-Based BVPI Summary for 2004/05 and 2003/04 Surveys
  > Visual Surveys Best Practice
 
 
 

 

 

 

 

 

UKPMS Health Check 2005

The UKPMS Support Contractor has developed an Annual Health Check of accredited UKPMS systems. The Health Check is intended to provide ongoing routine assurance that UKPMS systems continue to meet UKPMS requirements including the current rule set and BVPI definitions.

The Annual Health Check is only carried out on fully accredited UKPMS systems and supplements rather than replaces the UKPMS Comparability Tests. Passing the Comparability Tests continues to be a requirement for any new systems that wish to become UKPMS Accredited.

2005 Annual Health Check Results

The following systems have successfully completed the 2005 Annual Health Check:

Exor Corporation UKPMS by exor 2.2.2.4 (14 Dec 2005)

WDM Ltd WDM PMS version 4 (16 Dec 2005)

Symology Ltd Insight v2.2.1 (22 Dec 2005, see Notes below)

Faber Maunsell Ltd MARCHpms v3.02 (23 Feb 2006)

MapInfo Business Applications Confirm 5.00l.AM (8 Feb 2006, see Notes below)

Notes on Symology system: (1) Only the v2.2.1 system with a release date of 17 Jan 06 or later has been tested (2) The system does not check for or trap overlapping data (3) The system assigns the Overall CI and Ranking to 100 (rather than 0) for functional defect lengths (i.e. those generated by SCRIM or GripTester data)

Notes on Confirm system: (1) If two surveys (of the same type) are encountered for the same section then the older of the two survey sections will not be used if it shares any XSPs with the newer survey section. (2) The Owner field is mandatory for inventory data (3) The Probability based Road Condition Indicator report is not currently available. For more information about any of these notes please contact the UKPMS Support Contractor.

If you require any further information about the Annual Health Check or about the accreditation status of any UKPMS systems then please contact the UKPMS Support Contractor.




Principles & Objectives 029v0110.pdf
UKPMS Annual Health Check 2005 - Principles & Objectives version 1.10  
   

 

 

 

 

 

 

 

 

 
 
Produced by Chris Britton Consultancy Ltd on behalf of the UKPMS Owners Forum